UV resistant
Nominal cross section conductor (mm²)
Material core insulation
Core identification Colour
Weight (kg/km)
Flame retardant According to IEC/EN 60332-1-2
Circuit integrity
Stranding element
Colour outer sheath White
Category 3
Diameter conductor (mm) 0.41
Conductor material_EF001622 Copper
Screen over stranding element None
Screen over stranding Other
Material outer sheath Polyvinyl chloride (PVC)
Conductor category Class 1 = solid
Armouring/reinforcement
MIN - Permitted cable outer temperature during assembling/handling (°C)
MAX - Permitted cable outer temperature during assembling/handling (°C)
MIN - Permitted cable outer temperature after assembling without vibration (°C) -20
MAX - Permitted cable outer temperature after assembling without vibration (°C) 75
Number of stranding elements 4
Protective sheath
Number of cores 8
Suitable for underground installation
Halogen free (according to IEC 60754-2) Yes
Insulation integrity according to IEC 60331
Low smoke (according to IEC 61034-2) Yes
Stranding
Outer diameter approx. (mm) 7.5
Low smoke (according to EN 61034-2) Yes
NVP value (%)
Halogen free (according to EN 60754-1/2) Yes
Oil resistant (according to EN 60811-404)
Oil resistant (according to IEC 60811-404)
Conductor surface Bare
Longitudinal water blocking cable
Radial water blocking cable
Reaction-to-fire class according to EN 13501-6 Dca
Smoke development class according to EN 13501-6 s2
Euro class flaming droplets/particles according to EN 13501-6 d2
Euro class acidity according to EN 13501-6 a1
AWG size 26
Min. permitted bending radius, moving application with forced guidance (mm)
Min. permitted bending radius, moving application/free movement (mm)
Min. permitted bending radius, stationary app./permanent installation (mm)
Specification core insulation
Specification material outer sheath
Material reinforcement
Cable geometry
Core identification according to HD 308 S2
Suitable as telephone cable
Suitable as computer data cable
Suitable as signalling cable
Certified for shipboard application
Segregation class according to EN 50174-2
Approved type of underground installation
Compatible with Grade2TV according to XP-C 90-483
Compatible with Grade3TV according to XP-C 90-483
Nominal cross section conductor (in²)
Weight (lb/mile)
Diameter conductor (inch)
MIN - Permitted cable outer temperature during assembling/handling (°F)
MAX - Permitted cable outer temperature during assembling/handling (°F)
MIN - Permitted cable outer temperature after assembling without vibration (°F) -4
MAX - Permitted cable outer temperature after assembling without vibration (°F) 167
Outer diameter approx. (inch) 0.3
Min. permitted bending radius, moving application with forced guidance (inch)
Min. permitted bending radius, moving application/free movement (inch)
Min. permitted bending radius, stationary app./permanent installation (inch)