UV resistant No
Nominal cross section conductor (mm²)
Material core insulation Polyolefin
Core identification Colour
Weight (kg/km)
Flame retardant According to IEC/EN 60332-1-2
Circuit integrity None
Stranding element Pairs
Colour outer sheath White
Category 7
Diameter conductor (mm)
Conductor material_EF001622 Copper
Screen over stranding element Foil
Screen over stranding Foil
Material outer sheath Polyolefin
Conductor category Class 1 = solid
Armouring/reinforcement
MIN - Permitted cable outer temperature during assembling/handling (°C)
MAX - Permitted cable outer temperature during assembling/handling (°C)
MIN - Permitted cable outer temperature after assembling without vibration (°C) -20
MAX - Permitted cable outer temperature after assembling without vibration (°C) 75
Number of stranding elements 4
Protective sheath None
Number of cores 8
Suitable for underground installation No
Halogen free (according to IEC 60754-2) Yes
Insulation integrity according to IEC 60331 No
Low smoke (according to IEC 61034-2) Yes
Stranding Bundle
Outer diameter approx. (mm) 7.2
Low smoke (according to EN 61034-2) Yes
NVP value (%)
Halogen free (according to EN 60754-1/2) Yes
Oil resistant (according to EN 60811-404) No
Oil resistant (according to IEC 60811-404) No
Conductor surface Bare
Longitudinal water blocking cable No
Radial water blocking cable No
Reaction-to-fire class according to EN 13501-6 Dca
Smoke development class according to EN 13501-6 s2
Euro class flaming droplets/particles according to EN 13501-6 d2
Euro class acidity according to EN 13501-6 a1
AWG size 23
Min. permitted bending radius, moving application with forced guidance (mm)
Min. permitted bending radius, moving application/free movement (mm)
Min. permitted bending radius, stationary app./permanent installation (mm)
Specification core insulation Polyethylene (PE)
Specification material outer sheath Polyethylene (PE)
Material reinforcement Copper
Cable geometry Round
Core identification according to HD 308 S2 No
Suitable as telephone cable No
Suitable as computer data cable No
Suitable as signalling cable No
Certified for shipboard application No
Segregation class according to EN 50174-2
Approved type of underground installation
Compatible with Grade2TV according to XP-C 90-483 No
Compatible with Grade3TV according to XP-C 90-483 No
Nominal cross section conductor (in²)
Weight (lb/mile)
Diameter conductor (inch)
MIN - Permitted cable outer temperature during assembling/handling (°F)
MAX - Permitted cable outer temperature during assembling/handling (°F)
MIN - Permitted cable outer temperature after assembling without vibration (°F) -4
MAX - Permitted cable outer temperature after assembling without vibration (°F) 167
Outer diameter approx. (inch) 0.28
Min. permitted bending radius, moving application with forced guidance (inch)
Min. permitted bending radius, moving application/free movement (inch)
Min. permitted bending radius, stationary app./permanent installation (inch)