UV resistant Yes
Nominal cross section conductor (mm²)
Material core insulation
Core identification
Weight (kg/km)
Flame retardant No!
Circuit integrity
Stranding element
Colour outer sheath Yellow
Category 6
Diameter conductor (mm)
Conductor material_EF001622 Copper
Screen over stranding element
Screen over stranding
Material outer sheath
Conductor category Class 2 = stranded
Armouring/reinforcement
MIN - Permitted cable outer temperature during assembling/handling (°C) -40
MAX - Permitted cable outer temperature during assembling/handling (°C) 80
MIN - Permitted cable outer temperature after assembling without vibration (°C) -40
MAX - Permitted cable outer temperature after assembling without vibration (°C) 80
Number of stranding elements
Protective sheath
Number of cores
Suitable for underground installation No
Halogen free (according to IEC 60754-2)
Insulation integrity according to IEC 60331
Low smoke (according to IEC 61034-2)
Stranding
Outer diameter approx. (mm)
Low smoke (according to EN 61034-2)
NVP value (%)
Halogen free (according to EN 60754-1/2) No
Oil resistant (according to EN 60811-404) Yes
Oil resistant (according to IEC 60811-404)
Conductor surface
Longitudinal water blocking cable No
Radial water blocking cable
Reaction-to-fire class according to EN 13501-6
Smoke development class according to EN 13501-6
Euro class flaming droplets/particles according to EN 13501-6
Euro class acidity according to EN 13501-6
AWG size 24
Min. permitted bending radius, moving application with forced guidance (mm)
Min. permitted bending radius, moving application/free movement (mm)
Min. permitted bending radius, stationary app./permanent installation (mm)
Specification core insulation
Specification material outer sheath
Material reinforcement
Cable geometry
Core identification according to HD 308 S2
Suitable as telephone cable
Suitable as computer data cable
Suitable as signalling cable
Certified for shipboard application
Segregation class according to EN 50174-2
Approved type of underground installation
Compatible with Grade2TV according to XP-C 90-483
Compatible with Grade3TV according to XP-C 90-483
Nominal cross section conductor (in²)
Weight (lb/mile)
Diameter conductor (inch)
MIN - Permitted cable outer temperature during assembling/handling (°F) -40
MAX - Permitted cable outer temperature during assembling/handling (°F) 176
MIN - Permitted cable outer temperature after assembling without vibration (°F) -40
MAX - Permitted cable outer temperature after assembling without vibration (°F) 176
Outer diameter approx. (inch) 0.31
Min. permitted bending radius, moving application with forced guidance (inch)
Min. permitted bending radius, moving application/free movement (inch)
Min. permitted bending radius, stationary app./permanent installation (inch)